Proportional 1:128 | M128 Meter System

M128 Meter System

The M128 Meter System is best suited for high duty cycle 1:128 applications and includes:

Need Answers?

Item Number
Inquiry
Downloads

Select Stenner's M128 Meter System, pre-assembled and ready for installation, for 1:128 dosing to poultry water.

In livestock operations, stock solutions are traditionally run through non-electric water driven proportioners or medicators for 1:128 dosing of sanitizers, disinfectants, nutrients and medications. The water driven proportioner is prone to failure from chemicals deteriorating seals, pistons and O-rings. Debris and solids from the water source interfere with the operation and cause failure. The M128 Meter System doesn't have those issues.

Stenner's M128 medicator is unaffected by undiluted chemicals or debris from the water source. The solution is pumped through the suction line, peristaltic tube and discharge line so it doesn’t come in contact with the pump’s moving parts. The medicator injects directly into the water line eliminating the need for a water bypass. When there is power to the pump and when utilizing a house controller, the standby setting can stop the pump from injecting, due to the internal signal splitter, and still register water consumption to the controller.

The M128 Meter System is optimal for turnkey installations. The design includes the medicator and a dry contact water meter in an all in one system where the components are mounted at the factory on a heavy duty panel to affix to a wall. Select a 3/4" or 1", plastic water meter offered as 1, 2, 4 or 10 pulses per gallon or 1 pulse per liter.

Stenner's Unique Features

  • Easy and fast pump tube replacement without tools with the patent pending QuickPro® pump head.
  • Simple service with periodic tube and duckbill replacement.
  • The system provides convenient service accessibility.

How It Works

Activated by a dry contact water meter, the M128 pump is pre-set to ensure accurate delivery at 1 ounce per gallon and is adjustable for meter pulse rates of 1, 2, 4 or 10 pulses per gallon or 1 pulse per liter. The medicator is pre-set to work with the tube size in the selected model.

Click on output for pump sizing and specific output for each model.

M128 Meter System Installation Instructions
M128 Pump Manual
M128 Pump flyer

pdficon_smallTo view these documents, you need Adobe Acrobat Reader. You can download a free copy from the Adobe website.

0-25 psi (0-1.7 bar)

Output

ModelItem No.
Prefix
Pump
Tube #
M05M05#5
Ounces
per Minute
Gallons
per Hour
Gallons
per Day
Milliliters
per Minute
Liters
per Hour
Liters
per Day
Approximate Output @ 50/60Hz
8.43.995.0249.714.9359.6

Maximum system water flow for 1:128 dosing is 8.4 gallons/minute or 31.8 litters/minute.

26-100 psi (1.8-6.9 bar)

Output

ModelItem No.
Prefix
Pump
Tube #
M07M07#7
Ounces
per Minute
Gallons
per Hour
Gallons
per Day
Milliliters
per Minute
Liters
per Hour
Liters
per Day
Approximate Output @ 50/60Hz
3.51.640.01056.3151.4

Maximum system water flow for 1:128 dosing is 8.4 gallons/minute or 31.8 litters/minute.

Alternative Sizing For M07 Model Using 1 pulse/gallon Meter

Dosage oz/galDosage RatioMax. System Water
Flow gal/min
Pulse Setting
1.01:1283.51
0.501:2567.02
0.251:51214.04

NOTE: Injection check valve included with pumps rated 26-100 psi (1.8-6.9 bar)

exclamationNOTICE: The information within this chart is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment. Many variables can affect the output of the pump. Stenner Pump Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.

M128 Pump

Specifications
Maximum Operating Temperature104°F (40°C)
Maximum Suction Lift25 ft (7.6 m) vertical lift, based on water
Motor Type24VDC, 2.0 A, Brushed DC, 1/30 HP
Duty CycleContinuous
Motor Voltage (Amp Draw)120V 60Hz 1PH (0.5)
220V 60Hz 1PH (0.33)
Power Cord TypeSJTOW
Power Cord Plug End120V 60Hz NEMA 5/15
220V 60Hz NEMA 6/15
Materials of Construction
All HousingsPolycarbonate
Pump Tube & Check Valve DuckbillSantoprene®*, FDA approved
Pump Head RollersHDPE
Roller BushingsOil impregnated sintered bronze
Suction/Discharge Tubing,
Ferrules 1/4"
Polyethylene, FDA approved
Tube Fittings, Check Valve FittingsGray fittings: Type 1 Rigid PVC, NSF listed
Black fittings: PP, NSF listed
Connecting NutsPP or Type 1 Rigid PVC
Suction Line StrainerPP or Type 1 Rigid PVC body with Type 1
Rigid PVC cap, NSF listed; ceramic weight
All FastenersStainless steel
Pump Head LatchesPolypropylene

Agency Listings

Agency Listings

* Santoprene® is a registered trademark of Exxon Mobil Corporation.

 

Plastic Water Meter Flow Rates

Flow Rates*

SizeFlow Rate
gpm
Pulses
per Gallon
3/4"0.25 to 2212410
1"0.75 to 5012410
1 1/2"2.0 to 10012410


* Continuous Flow: The meter size should be selected based upon continuous flow, gpm, as opposed to pipe size.

Specifications
Accuracy±2% when operating between
minimum and maximum flow range
TemperatureRange 35-122°F (1.7-50°C)
Pressure Ratings15-100 psi (1.0-6.9 bar)
Maximum Current20mA
Maximum Voltage24VDC or VAC
SensorReed Switch
Cable Length6 ft (1.8 m)
Materials of Construction
Body**Engineered reinforced plastic (nylon)
InternalEngineered thermoplastic
MagnetAlnico

** 1 1/2" meter may include plastic or lead free brass couplings.

M128 pump

Shipping Weight: 10 lbs (4.5 kg)

Box Dimensions: 14 x 9 x 9 in. (35 x 23 x 23 cm)

 