Home  Products  Pumps  Econ V and F Series 
Back

Variable & Fixed Speed | Econ V and F Series

The Econ V and F Series

The Econ V and F series are compact, peristaltic pumps offering simple on and off metering for general light duty applications. The pumps are equipped with a wall adapter power supply.

Output

Econ V    1.4 to 40 gpd, 25 psi maximum
                

Econ F    11 to 54 gpd, 25 psi maximum
                

Need Answers?

Item Number
Inquiry
Downloads

The Econ V and Econ F are compact peristaltic pumps for simple metering applications.

Both the Econ V and the Econ F pumps are totally enclosed with a brushed motor for light duty or general intermittent applications. These compact pumps are equipped with a wall adapter power supply. The pumps work well for fluid transfer or sampling. They can inject solutions such as chlorine, acid, syrups, plating bath solutions, polyphosphates, corrosion inhibitors, biocides and a variety of other additives. 

Both pumps are designed with the patented quick release pump head for effortless and fast tube replacement without tools. The pump tubes are manufactured as a single piece construction. The tube fitting is overmolded to the tube material for a stronger connection. Each pump is equipped with a wall adapter power supply.

The Econ V is a variable speed pump and features an adjustable potentiometer.  The pump series has a selection of six different models with output ranges of 11 to 54 gallons per day with pressures to 25 psi.  (41.6 to 136.3 lpd / 1.7 bar).

The Econ F is a fixed output pump and is not adjustable. The pump runs at full speed when power is applied. There are six different models and the outputs are 11, 18, 22, 33, 36, or 54 gallons per day with pressures to 25 psi.  (41.6, 68.1, 83.3, 124.9, 136.3 or 204.4 lpd / 1.7 bar)
              
The pumps are wall mountable or select one of the optional mounting accessories. The Econ V or F is offered as a Tank System; the pump is shipped pre-mounted to a 7.5, 15 or 30 gallon solution tank. The pumps are cULus for indoor and outdoor use; CE IP44 is also available.

Unique Stenner Features

  • Effortless tube replacement with patented quick release pump head. VIEW VIDEO
  • Solid one piece tube construction
  • Mounting options

Advantages of Stenner's Peristaltic Pumps

  • Solution is not in contact with moving parts and runs through a food grade pump tube.
  • Pump head requires no valves, allows for easy maintenance.
  • Self-priming against maximum working pressure, foot valve not required.
  • Pump does not lose prime or vapor lock.
  • Pumps off-gassing solutions and can run dry.
  • Output volume is not affected by back pressure.

Econ Pump General Installation Video
Econ Pump Tube Replacement Video
Product Manual
Chemical Resistance Guide

pdficon_smallTo view these documents, you need Adobe Acrobat Reader. You can download a free copy from the Adobe website.

Econ V – Variable Speed Flow Rate Output Chart 25 psi (1.7 bar) maximum

Item No.
Prefix
Pump
Tube
Roller
Assembly
 
E10VLAAWhite
E20VLAAWhite
E10VLBBWhite
E20VLBBWhite
E10VLCCWhite
E20VLCCWhite
Gallons
per Day
Gallons
per Hour
Ounces
per Hour
 Ounces
per Minute
Liters
per Day
Liters
per Hour
Milliliters
per Hour
Milliliters
per Minute
Approximate Output @ 50/60Hz
1.4-10.00.1-0.47.6-53.30.1-0.95.4-37.90.2-1.6225.6-1579.23.8-26.3
2.3-16.00.1-0.712.2-85.30.2-1.48.7-60.60.4-2.5360.7-2525.06.0-42.1
2.9-20.00.1-0.815.2-106.70.3-1.810.8-75.70.5-3.2450.6-3154.27.5-52.6
4.6-32.00.2-1.324.4-170.70.4-2.817.3-121.10.7-5.0720.8-5045.812.0-84.1
4.3-30.00.2-1.322.9-160.00.4-2.716.2-113.60.7-4.7676.2-4733.311.3-78.9
6.9-48.00.3-2.036.6-256.00.6-4.326.0-181.71.1-7.61081.5-7570.818.0-126.2

Econ F – Fixed Flow Rate Output Chart 25 psi (1.7 bar) maximum

Item No.
Prefix
Pump
Tube
Roller
Assembly
E10FLAAWhite
E20FLAAWhite
E10FLBBWhite
E20FLBBWhite
E10FLCCWhite
E20FLCCWhite
Gallons
per Day
Gallons
per Hour
Ounces
per Hour
Ounces
per Minute
Liters
per Day
Liters
per Hour
Milliliters
per Hour
Milliliters
per Minute
Approximate Output @ 50/60Hz
11.00.558.71.041.61.71733.328.9
18.00.896.01.668.12.82837.547.3
22.00.9117.32.083.33.53470.857.8
36.01.5192.03.2136.35.75679.294.7
33.01.4176.02.9124.95.25204.286.7
54.02.3288.04.8204.48.58516.7141.9
exclamationNOTICE: The information within this chart is solely intended for use as a guide. The output data is an approximation based on pumping water under a controlled testing environment. Many variables can affect the output of the pump. Stenner Pump Company recommends that all metering pumps undergo field calibration by means of analytical testing to confirm their outputs.
Specifications
Output ControlEcon V: adjustable potentiometer
Econ F: fixed speed
Maximum Working Pressure25 psi (1.7 bar)                    
                       
Maximum Operating Temperature104°F (40°C)
Maximum Suction Lift25 ft (7.6 m) vertical lift, based on water
Motor Type24 VDC, brushed
Approximate Shaft RPM65 maximum (E20 models)
Duty CycleContinuous
Motor Voltage120 V 60Hz, 240 V 50Hz
Power Cord TypeSPT-2W
Power Cord Plug End2-prong wall transformer
ClassificationIndoor / Outdoor
Materials of Construction
All HousingsPolycarbonate
Pump TubeSantoprene®*, FDA approved
Pump Head RollersPolyethylene
Suction/Discharge Tubing
and Ferrules
Polyethylene, FDA approved
Tube and Injection FittingsPVC or Polypropylene, NSF listed
Connecting NutsPVC, NSF listed
Suction Line Strainer and CapPVC or Polypropylene, NSF listed, with Ceramic Weight
All FastenersStainless steel

Agency Listings

Agency logo UL and CE IP44

* Santoprene® is a registered trademark of Exxon Mobil Corporation.

Pump Dimensions


ECON-V-Dimensional-drawing
Shipping Weight:
4 lbs (1.8 kg)

Box Dimensions: 8 x 7 x 10 in. (20 x 18 x 25 cm)

 
 